MRI machine for your clinic, hospital or imaging centre

We sell MRI scanners for hospitals, private clinics, imaging centres and veterinary practices. The range covers superconducting systems at 1.5 and 3.0 Tesla, open permanent-magnet systems from 0.3 to 0.5 Tesla, a dedicated veterinary system and research systems. The price of an MRI scanner depends on the field strength, the bore diameter and the coils included in the configuration.

Every system arrives with transport, installation, commissioning and staff training. The conformity documentation and the user manual are handed over at installation, together with the commissioning report.

Context

What happens in practice

An MRI scanner is a major investment, and the chosen configuration sets the operating costs for the entire service life. The difference between a 1.5 and a 3.0 Tesla system shows in resolution and scan time, but also in price and siting requirements. Claustrophobic and overweight patients need a wide bore or an open architecture, and this option is decided before the order.

Siting brings its own requirements. The examination room needs radiofrequency shielding, and classic superconducting systems also require a helium installation with an emergency vent pipe. Without a siting plan prepared before the order, the fit-out costs can exceed the initial budget.

How we work

What we do

We start from the examinations you want to offer and from the space you have, not from the catalogue. For orthopaedics and routine examinations, an open permanent-magnet system has low operating costs and also accepts claustrophobic patients. For neurology and detailed examinations we recommend the superconducting systems at 1.5 or 3.0 Tesla. Based on this you receive a quote that covers the scanner, the coils, transport and installation.

Installation, calibration and staff training are included in the price. Many systems in the range run without liquid helium, so the site needs no vent pipe and the operating cost drops. After commissioning we remain responsible for service and parts, with the same contact for the entire service life.

Buying guide

How to choose an MRI machine

Open MRI or superconducting MRI

An open MRI machine with a permanent magnet, from 0.3 to 0.5 Tesla, has low running costs and accepts claustrophobic and larger patients. It is used for orthopaedics and routine examinations. Superconducting 1.5 and 3.0 Tesla systems have higher resolution and shorter scan times, suited to neurology and detailed examinations.

Wide bore for claustrophobic patients

Besides the open systems, the range includes the BroadScan-1.5 wide bore system, which keeps the image quality of a 1.5 Tesla system and reduces discomfort for claustrophobic patients.

Veterinary MRI and research MRI

The VET-1.5 veterinary MRI system is dedicated to veterinary clinics, for examining dogs, cats and other animals. For research we supply 7.0 Tesla small animal systems and 3.0 Tesla head MRI systems.

Siting and running costs

The examination room needs radiofrequency shielding. Conventional superconducting systems also need a liquid helium installation with a quench pipe. Many of the systems in our range work without liquid helium, so siting is simpler and running costs are lower.

Equipment

MRI imaging: models we supply

The models in the portfolio that cover this direction.

Superscan-3.0 Superconducting MRI System
Superconducting MRI

Superscan-3.0 Superconducting MRI System

3.0 Tesla superconducting MRI system with a short-bore magnet and zero helium consumption technology. Ultra-fast gradient engine, high-density integrated coils and an all-digital real-time spectrometer, for clinical diagnosis and research.

MagicScan-1.5 Superconducting MRI System
Superconducting MRI

MagicScan-1.5 Superconducting MRI System

1.5 Tesla superconducting MRI system with a short, high-homogeneity magnet that reduces claustrophobia. Complete imaging configuration with a high-performance gradient, integrated matrix coils and a digital spectrometer. Compact installation, no large-scale renovation.

BroadScan-1.5 Wide-Bore MRI System
Superconducting MRI

BroadScan-1.5 Wide-Bore MRI System

1.5 Tesla superconducting MRI system with an ultra-wide 70 cm bore and a short magnet. AI artifact suppression, low-noise design and integrated matrix coils. Designed for elderly patients, critically ill patients and other special populations, according to the manufacturer.

OPER-0.3 Open Permanent Magnet MRI System
Permanent Magnet MRI

OPER-0.3 Open Permanent Magnet MRI System

Open MRI with a 0.3 Tesla permanent magnet, a single-column C-type panoramic structure, an extra-wide opening and ample scanning space. Low operating and maintenance costs, AI-powered intelligent imaging system.

OPER-0.4 Open Permanent Magnet MRI System
Permanent Magnet MRI

OPER-0.4 Open Permanent Magnet MRI System

Open MRI with a 0.4 Tesla permanent magnet, a single-column C-type structure with a wide opening and spacious room that reduces claustrophobia. High-performance gradient, all-digital real-time spectrometer and high-density integrated coils.

OPER-0.5 Open Permanent Magnet MRI System
Permanent Magnet MRI

OPER-0.5 Open Permanent Magnet MRI System

Open MRI with a 0.5 Tesla permanent magnet, the top of the OPER range. Open C-type structure, ultra-fast gradient engine and digital spectrometer; the manufacturer indicates image quality and scanning speed equivalent to superconducting systems.

OPER-0.35 Open Permanent Magnet MRI System
Permanent Magnet MRI

OPER-0.35 Open Permanent Magnet MRI System

Open MRI for claustrophobic patients, with a 0.35 Tesla permanent magnet. Panoramic open C-type architecture with an ultra-wide opening, gradient self-shielding for cost control and expandable AI systems.

VET-1.5 Veterinary MRI System
Veterinary MRI

VET-1.5 Veterinary MRI System

1.5 Tesla veterinary MRI with a helium-free superconducting short-bore magnet. A V-shaped patient bed that reduces animal stress, a compact design with flexible siting and no ionizing radiation. Scans dogs, cats and exotic pets.

GreenMR BroadScan-1.5 Mobile MRI System
Research MRI

GreenMR BroadScan-1.5 Mobile MRI System

Helium-free mobile MRI system, 1.5 Tesla, with a conduction-cooled superconducting magnet and an open C-type architecture with an opening angle of at least 270 degrees. No quench tube, safe and easy to relocate, according to the manufacturer.

What clients ask us

MRI imaging: frequently asked questions

How much does an MRI machine cost?

The price of an MRI machine depends on the field strength, the bore diameter, the coils included and the magnet type. You receive a quote covering the machine, coils, transport, installation and team training.

What is the difference between a 1.5 Tesla and a 3 Tesla MRI?

A 3.0 Tesla system has higher resolution and shorter scan times, useful in neurology and detailed examinations. A 1.5 Tesla system covers most clinical examinations at a lower price and with simpler siting requirements.

Do you supply open MRI machines for claustrophobic patients?

Yes. We supply open MRI systems with permanent magnets of 0.3, 0.35, 0.4 and 0.5 Tesla and the BroadScan-1.5 wide bore system.

Do you supply veterinary MRI?

Yes, the VET-1.5 system is dedicated to veterinary clinics. We deliver it with transport, installation and team training.