Helium-free MRI system for clinics and research centres

We sell superconducting MRI systems that run without liquid helium, using a conduction-cooled magnet. The range includes clinical 1.5 Tesla systems, a 3.0 Tesla head scanner, a neonatal system for intensive care units, a mobile system and a 7.0 Tesla preclinical MRI for small animals. For manufacturers and integrators we also supply helium-free superconducting magnets with fields from 0.7 to 9.4 Tesla.

Every system arrives with transport, installation, commissioning and staff training. The conformity documentation and the user manual are handed over at installation, together with the commissioning report.

Context

What happens in practice

A classic superconducting MRI is cooled with liquid helium. The helium is topped up periodically, its price has risen steadily in recent years, and supply depends on a small number of producers worldwide. These costs add up over the scanner's entire service life and are hard to estimate at purchase.

Helium also brings siting requirements. A classic system needs an emergency vent pipe that runs through the building to the outside. In existing buildings or on upper floors, this pipe raises the fit-out cost and can block the project.

How we work

What we do

The systems in our range use conduction-cooled magnets and run without liquid helium. Periodic helium refills disappear and the emergency vent pipe is no longer needed, so the system can be installed in existing buildings and on upper floors. We start from the examinations you want to offer and from the space you have, and we tell you which model fits.

The quote covers the scanner, the coils, transport, installation and staff training. For medical equipment manufacturers, the superconducting magnets are delivered with technical documentation and integration support. After commissioning we remain responsible for service and parts, with the same contact for the entire service life.

Equipment

Machines for Helium-free MRI

The models in the portfolio that cover this direction.

Spin MRI Multi-Position Helium-Free MRI System
Helium-Free MRI

Spin MRI Multi-Position Helium-Free MRI System

Helium-free superconducting magnetic resonance imaging system, 1.5 Tesla, scanning at any position from 0 to 90 degrees: the patient can be examined standing, lying or tilted. The magnet rotates while energized, with no quench tube.

GreenMR Serenity 1.5T Helium-Free MRI System
Helium-Free MRI

GreenMR Serenity 1.5T Helium-Free MRI System

Magnetic resonance imaging system with a liquid helium free superconducting magnet, 1.5 Tesla. A 3-ton magnet with rapid installation and no specialized infrastructure. Not classified as a pressure vessel.

GreenMR Neo Neonatal Helium-Free MRI System
Helium-Free MRI

GreenMR Neo Neonatal Helium-Free MRI System

Helium-free pediatric MRI system dedicated to neonatal intensive care units. Ultra-quiet operation that allows scanning without sedation, AI motion artifact correction and an MRI-compatible transport incubator.

Lambda-0.7T-1125 Helium-Free Superconducting Magnet
Helium-Free Superconducting Magnets

Lambda-0.7T-1125 Helium-Free Superconducting Magnet

Liquid helium free superconducting magnet for MRI systems, 0.7 Tesla field, 1125 mm inner bore. The 1125 mm inner bore is presented by the manufacturer as the largest in the industry. Intended for intraoperative and interventional scenarios, including surgical navigation. Zero helium consumption, according to the manufacturer.

Delta-1.5T-500 Helium-Free Superconducting Magnet
Helium-Free Superconducting Magnets

Delta-1.5T-500 Helium-Free Superconducting Magnet

Liquid helium free superconducting magnet for MRI systems, 1.5 Tesla field, 500 mm inner bore. The most compact bore in the 1.5 Tesla range, for systems with a small footprint. Intended for clinical MRI systems. Zero helium consumption, according to the manufacturer.

Kappa-1.5T-605 Helium-Free Superconducting Magnet
Helium-Free Superconducting Magnets

Kappa-1.5T-605 Helium-Free Superconducting Magnet

Liquid helium free superconducting magnet for MRI systems, 1.5 Tesla field, 605 mm inner bore. Intended for clinical MRI systems. Zero helium consumption, according to the manufacturer.

Helium-free MRI: 1.5 and 3.0 Tesla systems, price and installation | Zeqira